August 2012L010184
S - Stop Soft
Format: S
Description: This command will cause the pulse generator to ramp down to base speed
and stop. It can only be used when pulses are running.
V - Verify
Description: This command can be used with most commands to verify the register con-
tents. This is a read only command. Valid Commands are: A, B, C, D, M, R, and +.
Format: V[command]
This format is good for C, D, R, and +.
C - If a 1 is sent back then the driver is in reduced current mode. If a 0 is sent
back then the driver is not in reduced current mode.
D - If a 1 is sent back then the pulse generator will ramp down to stop when the
Run/Stop input is released. If a 0 is sent back then the pulse generator will
stop hard when the Run/Stop input is released.
+ - If a 1 is sent back then the direction is clockwise. If a 0 is sent back then the
direction is counterclockwise.
Sample: V+ Verifi cation of Direction is prompted.
Format: V[command]# - Where # is the speed profi le number 1 thru 4
This format is good for A, B, and M.
A# - Verify Acceleration/Deceleration for given speed profi le.
B# - Verify Base Speed for given speed profi le.
M# - Verify Max speed for given speed profi le.
Sample: VB2 Verifi cation of Base Speed in Profi le 2 is prompted.