4 Lead Motors TYPICAL APPLICATION HOOK-UP
Use the specified series motor current to determine the current adjustment
resistor value. Four-lead motors are usually rated with their appropriate series
current, as opposed to the Phase Current which is the rating for 6 and 8 lead
motors.
8 Lead Motors
Series Connection: When configuring the motor windings in series, multiply
the per Phase (or unipolar) current rating by 0.7. Use this result to determine
the current adjustment pot setting.
Parallel Connection: When configuring the motor windings in parallel, multiply
the per Phase (or unipolar) current rating by 1.4. Use this result to determine
the current adjustment pot setting.
NOTE: After the current has been determined, according to the motor
connections above, follow the procedure Determining Output Current on page
7 to find the current value. Then use Table 3 to choose the proper pot setting.
WARNING: Do not connect or disconnect motor wires while power is applied!